Jump to content

Kyle Communications

Moderators
  • Posts

    6,572
  • Joined

  • Last visited

  • Days Won

    93

6 Followers

About Kyle Communications

  • Birthday 23/05/1959

Information

  • Aircraft
    ICP Savannah VG XL/ S and Rans S21 Outbound
  • Location
    Burpengary East
  • Country
    Australia

Recent Profile Visitors

The recent visitors block is disabled and is not being shown to other users.

Kyle Communications's Achievements

Well-known member

Well-known member (3/3)

  1. Yes it is a shame that you have been F@$ked over like this. yet there are a number of jabs flying that have had CAR35 i think it is. We had one at Caboolture airfield for a few years then it was sold. Not sure where it went to. I could find out if you want as I know the school operator. and it was RAA rego not GA I am sure. The new owner of jabiru hopefully sees the light and does one with a Rotax up the front hopefully he is not as pig headed as old Rodney about these things. They would sell a heap of Jabs with Rotax...there are still a lot of potential buyers out there that just dont trust the jab engine...I am not trying to start a flame war here just stating a fact. But now Stiffy is not the controlling partner maybe some improvements could be made as the Jab has been proved as a good safe airframe.
  2. I bought it to keep my bolly at the time in good nick for the engine. It has balanced quite a lot of engines now since I have had it. I have a L2 that borrows it a bit when servicing some aircraft even GA ones it has done. It was probably some overkill really for just my aircraft but at the time I was a bit flush and could spare the cost without a second thought. I of course do Eprop and they are all prebalanced but I dont think I would ever sell it. Its what I class as "test equipment"...There are some things I will never sell. That is all my very expensive RF test equipment and other electronic test gear also my lathe and my CNC Mill..There are some things once you manage to either fund or beg borrow or steal that you end up never selling. They only go when they are broken beyond repair or its by the execetor of your will....I think its a thing that most radio techs do. I bet if you ask RFGuy he doesnt get rid of his prized test equipment even if you only use it once a year 🙂
  3. I have a dynavibe..they work well. Bought it secondhand for about 1200 quite a few years ago now.
  4. No they are typically FETS..they are a voltage device rather than a current based device. Essentially they work like a switch when you place a voltage onto the gate and the drain and source then conduct. They are still semiconductors but they dont have any gain like a transistor does. I am trying to keep this as simple as I can because this subject is huge now. FETS are almost taking over the world 🙂 They are silicon switch for a better word. FETS are really common now and most of all your solar inverters and your power inverters etc..anything that switches on and off ans fast they are generally FETS now. They can take a crap load of current through them because their "on resistance" is very small. A lot of FETS have resistance across the junction like 0.28 of an ohm when turned on and even less. There is a mininum voltage that they turn on with but there is still a current limit as the junction resistance is not the lowest until the voltage gets to a higher level. There are so many types of FETS now its crazy...infact RF Output devices are commonly FETS now and are used regularly ...and I am talking lots of power. LDMOS type ones are regularly 1.5kw RF out Infact the main RF output device in a Xcom airband radio is a FET
  5. Skippy you wouldnt want to be running any starter motor current through that thing
  6. The wattage loss is very low even at 10 amps (6 watts max) which would be the most current drawn from a dual efis system and ancillaries. That is only while it is turned on. With semiconductors the limiting factor is the device's junction temperature. The reason I dont like relays is it is drawing all your avionics load current through a spade terminal. I much prefer the screw/boltability of the SSR to take all the load. As a case in point just look how many Rotax regulators end up with burnt out spade terminals on the regulators...I would know of 20 or 30 at least...I dont like them odds...its just not a good thing..Thats why AC43 pretty much specifies ring terminal connections when possible
  7. no he had a carb engine spring fail and the engine was running very rough so he put down on the island...emerg services came but they got it sorted and continued onto tasmania
  8. Where is Hogan Island?..There was a incident I know of in Bass Strait. but it wasnt a savannah
  9. Pictures and sizes of the SSR. also the heatsink on the back. I like too that you replace the screws with small bolts and all connections are on lugs not those stupid spade connectors
  10. I did mine a few weeks ago now...did the online stuff and filled out the stuff flashed my CC and literally 45 sec later my medical class 5 appeared in my email. Mark
  11. Nev I know the differences of each to me its the same result. Just different purposes. After 43 years as a electrical fitter mechanic special class ( industrial electronics) and also a radio tech....I think I know what versions are used for what tasks. Working on 11kv and 33kv and 110kv circuit breakers...using solenoid style actuation and distribution authority electrical substation protection and control systems using hundreds of relays also fault finding and contruction of those substation controls..The last 10 years also doing design and development of mains connected power electronics for mass production sets of products to me they are essentially the same just a different scale and type for the purpose. As I said its semantics to me. You just use the APPROPRIATE DEVICE for the job. As I stated I much prefer to use a manual isolation switch within my reach in the cabin rather than a solenoid to isolate a battery that I have my arse sitting in.
  12. WEEEEELL it is semantics really. A relay is still a electromagnet coil and so is a solenoid. The solenoid is a much larger device designed to switch a much larger load and it does have a core that moves internally. The relay is pretty much exactly the same but in a smaller footprint and designed to handle a lot less current but it does the same thing. The relay though does tend to have a "switch" as contacts being NO and NC but there are exceptions where there is only one set of contacts which are NO similar to a solenoid. so it could be semantics or it could be definition..either way they both do the same thing. Yes you could have a solenoid working off a master switch in the aircraft that does isolate the battery. I have seen plenty of "solenoids" fail in my work life and to be honest I dont think I have ever seen a properly rated isolation switch fail. It is a peronal choice I suppose which way you want to go. To me I like the big manual switch right where it can be accessed from the pilot position.
  13. When referring to a Master in a aircraft it usually means the main electric buss for the internal DC for the aircraft. Not the whole system for the aircraft including battery. I believe what you wanted was a isolation switch. I will always have a isolation switch for the very reasons you give above, That really is a given. The master is not that. It is just wordings I suppose and it all just means take accepted practices for making safe the whole electrical system in the aircraft. How far you want to go with that is up to the builder...and the rules of course. There is no requirement for a isolation switch in any aircraft...but it just makes good sense because if a fault like that occurrs you cant just get out of the vehicle at 7000 ft...unless you got a parachute on 🙂
  14. The SSR I posted is NOT for the starter motor to use it is only for the MASTER..which is for the internal DC for aircraft. The starter has a usual generic solenoid/relay to take the many hundreds of amps at start. I would never use it to switch starter motor current. Semantics of wether it is a solenoid or a relay is nit picking words...we all know what it is and what it does
  15. I always use continuous rated switches....none of this 20 sec stuff as they never cut the mustard. 100 to 200 amps continuous..same as this solid state relay its apparently 100 amps continuous Max Surge 260 amps for a short time..heaps of overkill for a master but solid state DC switches are a bit hard to get This mob below also sell Tefzel wire...it all mainly supplied for race cars on this site. But its local here in brisbane 12-24V 100A Solid State Relay WWW.NRTAUTOMOTIVE.COM.AU Solid state relays (SSR) have no moving parts, eliminating failures normally associated with conventional mechanical switching relays. Rated up to 100A, this SSR provides faster switching time, improved...
×
×
  • Create New...